GK800-4T315 Variable Frequency Drive

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Guangdong
Validity to: Long-term effective
Last update: 2017-07-07 12:07
Browse the number: 490
inquiry
Company Profile
 
 
Product details

GK800 Closed-loop Vector Control Variable Frequency Drive

GK800 Series High Performance Variable Frequency Drives, adopting most advanced close-loop vector control technology, are able to perform precise control on both asynchronous motors and permanent magnet synchronous motors. GK800 series, one of the real drives leaders, are superb in demanding applications with excellent performance no matter in speed control, torque control, position control, field weakening control, or response time, and so on.

GTAKE has dedicated frequency inverters for tension control purpose. GK800T frequency inverters mainly provide winding and unwinding requirements and have the tension control system of coiling diameter calculation. For details, please contact us or download the dedicated GK800T Instruction Manuals.

1. Distinctive advantages of  GTAKE close-loop vector control Variable Frequency Drive

Based on the top software and hardware elite, modern and scientific producing workmanship, rigorous quality control systems and management team, GTAKE Frequency Inverters have many advantages, some of which are listed as below:

• Apply to asynchronous AC motor and permanent magnet synchronous AC motor;
• Starting torque:180% at 0.25Hz (SVC pattern), 200% at 0Hz (VC pattern);
• Speed adjustable range: 1:200 (SVC pattern), 1:1000 (VC pattern);
• Speed accuracy: +/-0.2% (SVC pattern), +/-0.02% (VC pattern);
• Over load capability: 150% 1minute, 180% 10s, 200% 0.5s;
• Abundant frequency command sources;
• Diverse input and output terminals;
• Ambient temperature: -10°C~50°C;
• High precise torque constraint, process PID control, simple PLC, wobble frequency control, contracting brake control, field weakening control, all sides protection, etc.
• Online and offline autotune of motor parameters can both performed;
• Extremely short-time acceleration can be performed without any trip, such as 0.1s or 0s from 0Hz to 50Hz;
• No derating ambient temperature: -10-50 centigrade;
• Customized products and services are also welcome;
• Flexible command sources, parameters setting, and all sided equipment protection function automatically;
• The malfunction ratio is lower than 1% within warranty period, based on the statistics.

2. Wiring Diagram of GK800 High Performance AC Drives

3.Information of Product Model

Technical Features of GK800 series Motor  Frequency Inverters
3AC 380V/400V/415V/440V/460V/480V  -10%~10%, 50Hz/60Hz -5%~5%

Model

Power Rating (kW)

Rated Output Current (A)

Rated Input current (A)

Applicable motor (kW)

Brake unit

GK800-4T2.2B

2.2

5.5

9.2

2.2

Built-in

GK800-4T3.7B

3.7

9

14.9

3.7

GK800-4T5.5B

5.5

13

21.5

5.5

GK800-4T7.5B

7.5

17

27.9

7.5

GK800-4T11B

11

24

39

11

GK800-4T15B

15

30

50.3

15

GK800-4T18.5(B)*

18.5

39

60

18.5

Built-in optional

GK800-4T22(B)*

22

45

69.3

22

GK800-4T30(B)*

30

60

86

30

GK800-4T37(B)*

37

75

104

37

GK800-4T45(B)*

45

91

124

45

GK800-4T55

55

112

150

55

Externally mounted when needed

GK800-4T75

75

150

201

75

GK800-4T90

90

176

160**

90

GK800-4T110

110

210

192**

110

GK800-4T132

132

253

232**

132

GK800-4T160

160

310

285**

160

GK800-4T185

185

350

326**

185

GK800-4T200

200

380

354**

200

GK800-4T220

220

430

403**

220

GK800-4T250

250

470

441**

250

GK800-4T280

280

520

489**

280

GK800-4T315

315

590

571**

315

GK800-4T355

355

650

624**

355

GK800-4T400

400

725

699**

400

** means GK800-4T110  or above is provided with an external-mounted DC reactor in shipment as default
1AC/3AC  208V/220V/230V 50/60Hz -10%~10%, 50Hz/60Hz -5%~5%

Model

Power Rating (kW)

Rated Output Current (A)

Applicable motor (kW)

Brake unit

GK800-2T2.2B

2.2

10

2.2

Built-in

GK800-2T3.7B

3.7

16.5

3.7

GK800-2T5.5B

5.5

24

5.5

GK800-2T7.5B

7.5

30

7.5

GK800-2T11(B)

11

45

11

Built-in optional

GK800-2T15(B)

15

60

15

GK800-2T18.5(B)

18.5

73

18.5

GK800-2T22(B)

22

96

22

GK800-2T30

30

112

30

Externally mounted when needed

GK800-2T37

37

144

37

GK800-2T45

45

176

45

GK800-2T55

55

210

55

GK800-2T75

75

288

75

GK800-2T90

90

310(350)

90

GK800-2T110

110

415

110

4. Technical features of GK800 Variable Frequency Drive

Technical features of GK800 Variable Frequency Drive



     Power input

Rated input voltage

3-phase AC208V/220V/230V/240V/380V/400V/415V/440V/460V/480V

Rated input current

See Section 2.3 in the User Manual

Frequency

50Hz/60Hz, tolerance ±5%

Allowable range  of voltage

Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;

Voltage out-of-balance rate <3%,distortion rate as per the requirements of IEC61800-2

Power output

Applicable motor (kW)

See Section 2.3 in the User Manual

Rated current (A)

See Section 2.3 in the User Manual

Output voltage (V)

3-phase: 0~ rated input voltage, error < ±3%

Output frequency (Hz)

0.00~ 600.00Hz; unit: 0.01Hz

Overload capacity

150% - 1min; 180% - 10s; 200% - 0.5s

Control characteristics

V/f patterns

V/f control

Sensor-less vector control 1

Sensor-less vector control 2

Close-loop vector control (including position control)

Speed range

1:100 (V/f control, sensor-less vector control 1)

1:200 (sensor-less vector control 2)

1:1000 (close-loop vector control)

Speed accuracy

±0.5% (V/f control)

±0.2%(sensor-less vector control 1 & 2)

±0.02% (close-loop vector control)

Speed fluctuation

±0.3%(sensor-less vector control 1 & 2)

±0.1% (close-loop vector control)

Torque response

< 10ms (sensor-less vector control 1 & 2)

< 5ms (close-loop vector control)

Torque control accuracy

±7.5% (sensor-less vector control 2)

±5% (close-loop vector control)

Starting torque

0.5Hz: 180% (V/f control, sensor-less vector control 1)

0.25Hz: 180%(sensor-less vector control 2)

0Hz: 200% (close-loop vector control)

Positioning accuracy

±1 line pulse

Basic functions

Start frequency

0.00~ 600.00Hz

Accel/Decel time

0.00~60000s

Carrier frequency

0.7kHz~16kHz

Frequency command sources

Digital setting + keypad ∧/∨

Digital setting + terminal UP/DOWN

Communication

Analog setting (AI1/AI2/AI3)

Terminal pulse setting

Motor started methods

Started from starting frequency

DC brake then started

Speed search started

Motor stopped methods

Ramp to stop

Coast to stop

Ramp to stop + DC brake

Basic functions

Dynamic brake capacity

Brake unit threshold voltage: 650V~750V; service time: 0.0~100.0s; brake units of GK800-4T45 and below are built in or can be built in. See table 2-1

DC brake capacity

DC brake start frequency: 0.00~600.00Hz

DC brake current: 0.0~100.0%

DC brake time: 0.0~30.00s

Input terminals

7 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input.

3 analog inputs, one of which supports voltage input only, and the other two are voltage/current    programmable.

Output terminals

One high-speed pulse output terminal, 0~50kHz square signal; can output command frequency, output frequency and so forth

One digital output terminal

Two relay output terminals

Two analog output terminal, voltage/current programmable; can output command frequency, output frequency and so forth

Encoder signal terminal

Compatible with 5V/12V encoder

Compatible with different types of encoder signal input, such as open collector, push-pull and differential, etc.

Featured functions

Parameter copy, parameter backup,common DC bus, free switchover between two motors' parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, reliable speed search started, a variety of Accel/Decel curves programmable, automatic correction of analog, contracting brake control,16-step speed control programmable (2 steps support flexible frequency command), wobble frequency control, fixed length control, count function,three faults recorded, over excitation brake, over voltage stall protection programmable, under voltage stall protection programmable, restart upon power loss, skip frequency, frequency binding, four kinds of Accel/Decel time,motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, asynchronous and synchronous motor parameter identification, field-weakening control,high-precision torque control, V/f separated control, torque control at sensor-less vector control, torque control at close-loop vector control, two encoder signal inputs (support incremental, UVW hybrid and resolver, etc.),flexible deceleration ratio control, zero servo, motor spindle orientation,simple feed forward control, pulse train position control

Protection function

Refer to Chapter 7 - Troubleshooting

Environment

Place of operation

Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water    drop and salt, etc.

Altitude

0~2000m

De-rate 1% for every 100m when the altitude is above 1000 meters

Ambient temperature

-10℃~50℃

Relative humidity

0~95%, no condensation

Vibration

Less than 5.9m/s2 (0.6g)

Storage temperature

-40℃~+70℃

Others

Efficiency at rated Amps

7.5kW and below: ≥93%

11~ 45kW: ≥95%      55kW and above: ≥98%

Installation

Wall-mounted

IP grade

IP20

Cooling method

Fan cooled

5. Environment requirement:

→Conditions: Indoors, free from direct sunlight, corrosive gases, flammable gases, oil mist, water vapor, metal particles, etc.
→Altitude: 0~2,000m. Derating is required above 1,000m, Rated output current should be derated 1% per 100m increase above 1000m.
→Ambient temperature: -10°C~50°C.Derating 1% per centigrade additional for temperature >50°C
→Vibration: Less than 5.9 m/s² (0.6g)
→Storage temperature: -40~70°C
→Protection grade: IP20
→Type of cooling: Air cooling
6. Applications:

Fan, oil pump, water pump, compressor, air compressor, injection molding machine, engraving machine, textile, packaging, conveyor, treadmill, printing machine, lathe, machine tool, hydraulic machine, wire drawing, winder/un-winder, knitting Machine, compressor, extruding machine, injection machine, AC motor, braiding machine, pressure fan, forced draught blower, blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine, slitter, Cutting machine, grinder, cluster, glazing machine, polisher, polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine.

7. Key words

Frequency inverters, AC Drives, variable frequency drives (VFD), AC motor drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable speed drives (VSD), AC motor speed controller, AC variable frequency drive, variable frequency inverter, AC motor speed controller, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, Servo Drive, Servo Motor & Drive, Servo Motor & Drive System

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]